Source Combined Rotary Dehumidifier for Industrial, Commercial, and Residential Use
Explore 16 combined rotary dehumidifier options for industrial, commercial, and residential applications. Compare specifications such as dehumidification capacity, power supply, and certifications like CE and RoHS to find the right unit for your facility; compare the available evidence and request quotations based on your requirements.
Key considerations
Products List


$600.00 - $3000.00
Moq: 1














Comprehensive Sourcing Guide
Combined Rotary Dehumidifier Sourcing Guide
Procurement teams must first distinguish between the rotary desiccant technology implied by the core keyword and the refrigerative units currently dominating the observed listings. The available data highlights specific refrigerative models with capacities ranging from 4kg/H to 20L/D, which operate on standard compressor cycles rather than rotating desiccant wheels. Buyers seeking true rotary systems must verify that the supplier possesses the specific desiccant wheel technology, as the current catalog primarily features integral or mobile cooling units with automatic humidistat controls.
When evaluating the current market signals, it is critical to note that the observed products are largely general-purpose refrigerative dehumidifiers suitable for environments between 5 and 40 degrees Celsius. These units often feature adjustable humidistats and automatic defrost functions, yet they lack the high-temperature tolerance or continuous regeneration cycles typical of rotary designs. Sourcing strategies should therefore focus on clarifying whether the supplier can bridge the gap between these standard refrigerative offerings and the specialized rotary requirements of industrial applications.
Product Scope and Observed Listing Signals
The current product landscape reveals a wide variance in dehumidification capacity, with observed models ranging from 4kg/H to 20L/D depending on the specific model series and environmental conditions. Listings indicate that units like the WL-CFB series offer capacities of 4kg/H, 5kg/H, 6kg/H, and 8.8kg/H, while the HK900BE model targets a daily rate of 20L/D. Buyers must carefully cross-reference these specific model numbers against their actual humidity load calculations, as the rated power consumption varies significantly from 240W to 3650W across the different configurations.
Listing signals also suggest a strong presence of mobile and integral structures designed for home or general commercial use, with air flow rates spanning from 140m³/H to 800m³/H. The observed noise levels range from 44db(a) to 54db(a), indicating that quieter models are available for residential settings while higher-capacity units may generate more acoustic output. Procurement teams should prioritize verifying the applicable area specifications, which are listed between 50 and 150 square meters, to ensure the selected unit matches the physical dimensions of the intended space.
Technical Specifications to Verify
Buyers must rigorously verify the power supply compatibility, as the observed listings support both single-phase 220V50Hz and three-phase 380V 3n50Hz configurations. The rated power for these units spans from 1100W to 3650W, meaning that electrical infrastructure must be capable of handling the maximum load without tripping breakers. It is essential to confirm the specific voltage requirements for the target model, as mismatched power supplies can lead to equipment failure or inefficient operation in the field.
Control precision and environmental suitability are equally critical technical parameters that require validation against site conditions. The observed control precision is listed at ±3%Rh, with humidity control ranges spanning from 10% to 90% relative humidity. Furthermore, the suitable operating temperature is noted between 5 and 38 degrees Celsius for some models and up to 40 degrees Celsius for others. Procurement teams must ensure the selected unit can maintain performance within the specific temperature and humidity constraints of the installation environment.
Compliance and Safety Documentation
Safety documentation must include valid CE, RoHS, GS, and CB certifications, as these are explicitly listed for the observed product lines. The presence of SASO certification is also noted, which is vital for suppliers targeting markets in the Middle East and North Africa. Buyers should request current certificates for each specific model to ensure that the manufacturing batch complies with the regulatory standards of the destination country, as certification status can vary between different production runs.
In addition to general safety marks, functional safety features such as automatic defrost and bucket full indicators are standard in the observed listings. These features are crucial for preventing water damage and ensuring continuous operation without manual intervention. Procurement teams should verify that the automatic humidistat control and external drain connectivity are fully functional and documented in the user manual, as these components directly impact the reliability and safety of the dehumidification process in unattended environments.
Cost Drivers and Commercial Terms
The observed price range spans from 1 USD to 100,000 USD, reflecting a vast difference between small residential units and large industrial systems. This wide variance suggests that cost is heavily driven by the dehumidification capacity, power rating, and the complexity of the control systems included. Buyers should expect that units with higher air flow rates, such as those exceeding 800m³/H, or those with advanced features like LED displays and washable filters, will command a premium price point.
Commercial terms are further influenced by the minimum order quantity, which ranges from 1 to 294 units across the observed listings. Customization is available for many models, which can significantly alter the final cost and lead time depending on the specific modifications requested. Procurement teams must negotiate clearly on whether customization fees are included in the unit price or billed separately, and they should clarify the payment terms associated with large volume orders to avoid unexpected financial liabilities.
Supplier Qualification and Quality Control
Quality control processes must verify that the product origin is China, as indicated in the supplied facts, and that the manufacturing standards align with international expectations. The observed products utilize specific refrigerant types like R22, which requires suppliers to demonstrate compliance with environmental regulations regarding refrigerant handling and disposal. Buyers should request evidence of the supplier's quality management systems to ensure consistent production of units with the specified gross and net weights.
Packaging standards are another critical aspect of supplier qualification, with cartons being the standard packing method for the observed models. The structural integrity of the packaging must be sufficient to protect the unit during transit, especially for heavier models with a gross weight of up to 47kg. Procurement teams should inspect sample packaging to ensure it meets the requirements for stacking and handling, preventing damage that could compromise the internal components like the fan and compressor.
Long-Term Procurement Checks
Long-term procurement strategies should focus on the availability of spare parts and the durability of key components like the fan and air filter. The observed listings mention washable air filters and removable water tanks, which are essential for reducing maintenance costs over the product lifecycle. Buyers must confirm the lead time for replacement parts and the availability of service manuals to ensure that the equipment can be maintained efficiently without significant downtime.
Finally, buyers should establish a protocol for periodic performance testing to verify that the dehumidification rate remains consistent with the rated specifications over time. The nominal dehumidification rate of 2.25kg/H at 27℃-Rh60% and the daily rate of 90L/D at 30℃-Rh80% serve as benchmarks for these checks. Regular audits of the unit's performance against these standards will help identify any degradation in efficiency early, allowing for timely repairs or replacements to maintain optimal operational conditions.
FAQs
What dehumidification capacity do these combined rotary dehumidifiers offer?
Listed models cover a range of capacities, from about 4 kg/H up to 8.8 kg/H for the WL-CFB series, and 10 to 20 kg/H for the AHLD N03B type. A home-oriented HK900BE unit is rated at 20 liters per day. Choose capacity according to room size, floor height, and target humidity level.
Can the dehumidifier run automatically without constant supervision?
Yes, automatic control is a listed attribute across the products. Functions include automatic humidistat control with around plus or minus three percent RH precision, automatic defrost, and auto restart on some models. A timing function is also available, so the unit can operate on a set schedule and maintain your chosen humidity unattended.
Which humidity settings can I select on these units?
Adjustable humidistat control is standard, and one listed model supports a humidity range of RH 10% to 90% with plus or minus 3% RH control precision. This lets you set a target level suited to storage, processing, or comfort needs. The controller then cycles the unit automatically to hold that setting.
How are the units powered and how much electricity do they use?
Power supply options include 220V~50Hz and 380V 3N~50Hz for larger models, while the home unit runs on 220-240V~50Hz. Rated power spans roughly 1100W to 3650W for commercial models, and the home model consumes about 240W. Check your local supply and circuit capacity before ordering.
What operating temperature range suits these dehumidifiers?
Suitable temperature is listed at 5 to 38 degrees Celsius for one series and 5 to 40 degrees Celsius for another, so they work in cool basements through warm industrial spaces. Automatic defrost helps in colder conditions. Avoid using them below the stated minimum, as coil frosting reduces performance.
Can I connect a continuous drain instead of emptying a tank?
Yes, the home model includes a removable water tank with a bucket-full indicator and also supports external drain connection, so you can drain continuously. Commercial integral units are designed with drainage in mind too. Confirm drain placement and hose routing for your installation space before setup.
Which certifications do these dehumidifiers carry?
Listed certifications include CE and ISO, with SASO noted for the AHLD series, and CE with RoHS for others, plus GS and CB on the home model. Certification requirements vary by destination market, so confirm which certificates your import region requires and request supporting documents from the supplier before purchase.
What are the physical characteristics and installation requirements?
The WL-CFB series is an integral, overall-mobile structure with casters implied by mobility, while one listed unit measures 492 by 405 by 1040 millimeters and weighs about 47 kg. The home unit weighs 13.5 kg. Units include a fan and washable air filter, so leave clearance around air inlets and outlets for airflow.